加长臂挖掘机发动机冒黑烟故障检查

日期:2019-08-08   来源:
  加长臂挖掘机发动机高温挡车、冒黑烟故障检查
  Inspection of High Temperature Blocking and Black Smoke Fault of Extended Arm Excavator Engine
  1.检查挖掘机液压先导压力是否在正常范围内。
  1. Check whether the hydraulic pilot pressure of excavator is in the normal range.
  2.在正常范围内,然后继续检查挖掘机主泵的压力值,看主泵是否有问题。
  2. In the normal range, then continue to check the pressure value of the main pump of excavator to see if there is any problem with the main pump.
  3.主泵压力值正常,说明主泵没有问题。
  3. The normal pressure value of the main pump indicates that the main pump has no problem.
  4 .因为挖掘机的工作也是高温锅,所以他们要清洗水箱,检查挖掘机风扇皮带的磨损情况,并且挖掘机的恒温器没有卡住,太原挖掘机的水泵水循环良好。
加长臂挖掘机
  4. Because the excavator works in a high temperature pot, they have to clean the water tank, check the wear and tear of the fan belt of the excavator, and the thermostat of the excavator is not jammed. The pump water circulation of Taiyuan excavator is good.
  5.风机皮带、水泵、伸缩臂挖掘机租赁、恒温器等均无问题,清洗水箱后水温依然较高。
  5. Fan belt, water pump, telescopic boom excavator rental, thermostat, etc. are no problem, the water temperature is still high after cleaning the water tank.
  6.由于挖掘机更换增压器的情况比较接近,怀疑增压器不匹配,所以进行了检查。
  6. Because the situation of replacing supercharger of excavator is close, it is suspected that supercharger does not match, so it is checked.
  7.经检查发现增压器是匹配的,因此拆除了重庆挖掘机中冷器,增压器直接与进气口连接,检查是否存在故障。
  7. The supercharger was found to be matched by the inspection, so the intercooler of Chongqing excavator was dismantled. The supercharger was directly connected with the intake port to check whether there was a fault.
  排除故障后,取出中冷器,发现中冷器堵塞。
  After troubleshooting, take out the intercooler and find that the intercooler is blocked.
  以上是加长臂挖掘机厂家为大家整理的内容,想要了解更多信息,欢迎访问网站:
  For more information, please visit the website: .

【本站图片均由网站所有方提供,部分图片来源于网络,如无意中侵犯了某媒体或个人的知识产权,请来信或来电告之,本网站将立即删除。】